OIL DIFFERENTIAL PRESSURE SWITCH

Main features:High-precision monitoring: It can accurately monitor the oil pressure difference in the system to ensure stable operation of the system.Reliability: The use of high-quality materials and precision manufacturing processes ensures that the switch can work stably in various environments.Easy to install: The compact design and easy installation are suitable for various systems.Durability: It has good corrosion resistance and wear resistance, and prolongs the service life.Safety: It has an overload protection function to prevent the system from being damaged due to excessive or low pressure.Manual reset: It has a manual reset function to simplify operation and maintenance.

Variants

OIL DIFFERENTIAL PRESSURE SWITCH

Category: PRESSURE CONTROL

Share On

The oil pressure differential switch is designed to monitor the oil pressure difference in industrial equipment. Its core component is a precision pressure controller, which adopts a white body design and has a compact and durable overall structure.

The top of the controller is equipped with a red emergency stop button and a blue adjustment knob for easy operation and setting. The red button is usually used to quickly cut off the power or pressure source in an emergency to ensure the safety of the equipment and operators. The blue knob is used to adjust the pressure threshold to meet the needs of different application scenarios.

On the upper part of the controller, there is a clear digital display that can display the current oil pressure value in real time. The values ​​of "0", "25", "30" and so on displayed on the screen represent different pressure levels. Users can use these values ​​to judge the current operating status of the equipment.

Under the controller, there are two copper connectors connected, which are used to connect and output oil pressure signals respectively. The connector on the left is circular and the connector on the right is hexagonal. This design not only facilitates users to connect pipes and lines, but also ensures the stability and reliability of the connection.

This product is also specially marked with "HEATERCIRC MOTORCIRC 110V (M):MANUAL RESET RESISTANCE DIFF PRESS RISING", which means that this oil pressure differential switch is suitable for 110V voltage system of heater circulation and motor circulation, and has manual reset function. When the oil pressure difference exceeds the preset threshold, the switch will automatically cut off the circuit to protect the equipment from damage. At this time, the user needs to manually press the reset button to restart the device.

In addition, this product also has the advantages of high precision, high stability and long life, and can adapt to various harsh industrial environments. Whether it is petroleum, chemical, machinery or power industries, this product can provide reliable pressure monitoring and protection functions.

logo
Guangzhou Baida Refrigeration Equipment Co., Ltd

People who viewed this also viewed

BAIDA

KP2 DANFOSS PRESSURE CONTROLLER

Danfoss KP2 pressure controller is a high-precision pressure control device for refrigeration and air conditioning systems, mainly used to protect the system from too low suction pressure or too high discharge pressure. It can also be used to start and stop the refrigeration compressor or air-cooled condenser fan, ensuring the safe and efficient operation of the system.Main featuresPressure adjustment range:Low pressure side: -0.20 bar to 5.00 bar (-2.9 psi to 72.5 psi).Pressure difference adjustment range:Low pressure side: 0.40 bar to 1.50 bar (6 psi to 21.8 psi).Reset function: automatic reset.Electrical connection:Electrical connection type: rotating cable connector.Electrical connection size: NPSM 1/2 - 14.Contact function: single pole double throw (SPDT).Contact rating:120 VAC, 16 FLA, 96 LRA.240 VAC, 8 FLA, 48 LRA.240 VDC, 12 W (0.05 A).Ambient temperature range:-25°C to 65°C (-13°F to 149°F).Maximum ambient temperature can reach 80°C (176°F), but only for a maximum of 120 minutes.Protection rating: IP30.Pressure connections:Connection type: Flare nut.Connection size: 1/4 in.

BAIDA

KP15 DANFOSS PRESSURE CONTROLLER

Main features1. Pressure adjustment range:Left side (low pressure side): -0.20 bar to 7.50 bar (6 inHg to 108 psig).Right side (high pressure side): 8.00 bar to 32.00 bar (116 psig to 464 psig).2. Pressure difference adjustment range:Left side: 0.70 bar to 4.00 bar (10 psi to 58 psi).Right side: 4.00 bar (58 psi).3. Reset function:Left side (low pressure side): automatic reset.Right side (high pressure side): manual reset.Contact function: single pole double throw (SPDT) + single pole single throw (NO).Contact rating: AC15=10 A, 400 V.Ambient temperature range: -40°C to 65°C (-40°F to 149°F).Protection level: IP30.Pressure Connections:Type: Welding joint (ODF) or flare nut.Size: 1/4 in.

BAIDA

KP36 DANFOSS PRESSURE CONTROLLER

1. Basic propertiesBrand: DanfossModel: KP36Type: Gas pressure controllerMeasurement accuracy: 0.05Measurement range: -0.05~1.4 (the specific measurement range may vary depending on the application, such as -0.2~7.5bar or 2.0~14.0bar, etc.)2. Functional featuresProtect refrigeration compressor: used to protect refrigeration compressors in refrigeration or air conditioning equipment to prevent the compressor's suction pressure from being too low or the exhaust pressure from being too high.Control start and stop: can be used to control the start and stop of refrigeration compressors and air-cooled condenser fans.Single-pole double-throw switch: equipped with a single-pole double-throw (SPDT) switch, the switch position is determined according to the set value of the pressure controller and the pressure at the interface.Ultra-short vibration time: minimize wear and increase the life of the controller.Manual control: no thermal core tool is required to perform electrical contact function tests.Vibration and shock resistance: compact design and vibration and shock resistance, suitable for industrial environments.Laser welded bellows: Using laser welded bellows as pressure sensing elements improves product reliability and stability.

BAIDA

KP35 DANFOSS PRESSURE CONTROLLER

Main features1. Wide adjustment range: The adjustment range of KP35 pressure controller is usually -0.2~7.5bar (the specific range may vary depending on the model), which can meet the needs of different application scenarios.2. Small size and easy to install: The compact structural design makes the KP35 pressure controller easier to install and saves space.3. Anti-vibration and shock: The use of high-quality materials and advanced manufacturing technology makes the KP35 pressure controller have good anti-vibration and anti-shock performance.4. Ultra-short flutter time: The contact wear is reduced to a minimum, which greatly increases the reliability of the controller.5. Front-end wiring: Easy to install in the control cabinet, saving time.6. AC and DC dual-use: Suitable for different power supply environments.

BAIDA

KP5 DANFOSS PRESSURE CONTROLLER

Product Features1. High performance and reliability:With a single-pole double-throw (SPDT) switch, the action point is accurate and reliable.The short vibration time effectively reduces contact wear and increases the life of the controller.The fail-safe bellows design improves vibration and impact resistance.2. Easy operation and maintenance:Manual control function, electrical contact function test can be performed without tools.Compact structural design, easy installation and maintenance.3. Safety protection:The housing with protection level of IP30 and IP44 can be configured to provide additional safety protection.4. Wide applicability:Applicable to various refrigeration and air conditioning systems to meet the needs of different application scenarios.

BAIDA

KP1 DANFOSS PRESSURE CONTROLLER

Product Features1. With single-pole double-throw (SPDT) conversion switch: the action point is determined according to the set value of the pressure controller and the pressure at the interface.2. High protection level: the shell with protection level of IP30 and IP44 can be configured to improve the durability and safety of the product.3. Short vibration time: effectively reduce wear and improve the reliability and service life of the controller.Vibration and shock resistance: the product design takes into account the vibration and shock resistance performance to ensure stable operation in harsh environments.4. Convenient manual control: the electrical contact function test can be carried out without the help of any tools, which is convenient for users to debug and maintain.5. Compact structural design: compact structure, small space occupation, easy to install and use.

BAIDA

HONGSEN PRESSURE CONTROL HS-P830

Features and Functions:Power Supply Voltage: The device is marked with "Electro data AC (250V) 8A", indicating that the device may support 250 volts AC, 8 amps power input.Differential Pressure Range: There are two dials on the device, showing "DIFF" and "RANGE". These dials may be used to set and display the current differential pressure value and the measuring range of the device.Reset Function: There is a "PUSH TO RESET" button on the device, which may be used to manually reset the device or clear an alarm state.Measurement Units: The differential pressure dial is marked with "bar" and "psi", indicating that the device can display the pressure difference in bar and pounds per square inch (psi).Connection Ports: There are two connection ports on the bottom of the device, which are usually used to connect to the pipeline system in order to measure the pressure difference between two different points.Material: The connection ports and part of the housing are made of brass or other corrosion-resistant materials to adapt to different industrial environments.

BAIDA

PRESSURE SENSORS

Pressure sensorApplication: Suitable for refrigeration system, hydraulic system, pneumatic system, automobile, medical equipment, etc.Main features:High-precision measurement: It can accurately measure the pressure of gas or liquid to ensure the precise control of the system.Reliability: The use of high-quality materials and precision manufacturing process ensures that the sensor can work stably in various environments.Durability: It has good corrosion resistance and wear resistance, and prolongs the service life.Easy to install: The design is compact and easy to install, suitable for various systems.Multiple output options: It provides a variety of output signal options, such as analog signals (such as 0-5V, 0-10V, 4-20mA, etc.) and digital signals.

BAIDA

OIL DIFFERENTIAL PRESSURE SWITCH

Main features:High-precision monitoring: It can accurately monitor the oil pressure difference in the system to ensure stable operation of the system.Reliability: The use of high-quality materials and precision manufacturing processes ensures that the switch can work stably in various environments.Easy to install: The compact design and easy installation are suitable for various systems.Durability: It has good corrosion resistance and wear resistance, and prolongs the service life.Safety: It has an overload protection function to prevent the system from being damaged due to excessive or low pressure.Manual reset: It has a manual reset function to simplify operation and maintenance.

BAIDA

DUAL PRESSURE SWITCH

1. Main features:High precision: It can accurately monitor and control two different pressure points in the system to ensure stable operation of the system.Reliability: The use of high-quality materials and precision manufacturing processes ensures that the switch can work stably in various environments.Easy to install: The design is compact and easy to install, suitable for various systems.Durability: It has good corrosion resistance and wear resistance, and prolongs the service life.Safety: It has an overload protection function to prevent the system from being damaged due to excessive or low pressure.Automatic reset: It has an automatic reset function to simplify operation and maintenance.2. Safety precautions:Electrical safety: Make sure that the wiring of the switch meets the electrical safety standards to avoid electric shock and short circuit.Mechanical safety: When installing and maintaining the switch, appropriate protective measures should be taken to avoid mechanical injuries.3. Packaging and transportation:Packaging: The switch is packed in cartons with foam lining to ensure safety during transportation.Transportation: The switch should avoid severe vibration and collision to prevent damage.